Repository logo
 
Publication

Experimental tests of partially encased beams at elevated and room temperature

dc.contributor.authorPiloto, P.A.G.
dc.contributor.authorRamos Gavilán, Ana Belén
dc.contributor.authorMesquita, L.M.R.
dc.contributor.authorBarreira, Luísa
dc.contributor.authorGonçalves, Carlos
dc.date.accessioned2014-10-28T16:41:54Z
dc.date.available2014-10-28T16:41:54Z
dc.date.issued2012
dc.description.abstractThis work presents the experimental tests developed on partially encased beams (PEB) at elevated temperature and room temperature. PEB were built with IPE100 steel profile. Two beam lengths were tested (2.5 and 4 m) at room, 400 and 600 ºC. Seven series were tested to compare the performance of PEB using two different stirrups shear conditions (welded -W and not welded to web - NW). The behaviour of IPE 100 PEB was also compared with IPE 100 bare steel beam at room temperature. Most of the beams attained the ultimate limit state by lateral torsional buckling (LTB), with exception for those tested at 600 ºC which collapsed by the formation of a plastic hinge (PH). The performance of each PEB was characterized based on some load events. The load value for plastic behaviour (FMpl), the load value for displacement equal to L/30 (FL/30) and the load value for the ultimate load (Fu). The bending strength of the PEB at room temperature is almost two times the bending resistance of bare steel beam. The reduction on bending resistance of PEB is not directly proportional to the increase of temperature. An increase of temperature from room to 400ºC and to 600ºC leads to a reduction of 37 % and 64% on FL/30, respectively. The ultimate load of PEB increased 85% in comparison with bare steel at room temperature. A decrease in the ultimate load of 24% and 22% was verified when temperature increased from room to 400 ºC and from 400 ºC to 600 ºC, respectively. The bending resistance of PEB without welded stirrups slightly decreased in comparison to PEB with welded stirrups.por
dc.identifier.citationPiloto, P.A.G.; Gavilán, Ana; Mesquita, L.M.R.; Barreira, Luísa; Gonçalves, Carlos (2012). Experimental tests of partially encased beams at elevated and room temperature. In 15th International Conference on Experimental Mechanics. Porto, Portugalpor
dc.identifier.urihttp://hdl.handle.net/10198/11130
dc.language.isoporpor
dc.peerreviewedyespor
dc.titleExperimental tests of partially encased beams at elevated and room temperaturepor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlacePortopor
oaire.citation.endPage15por
oaire.citation.startPage1por
oaire.citation.title15th International Conference on Experimental Mechanicspor
person.familyNamePiloto
person.familyNameMesquita
person.familyNameBarreira
person.givenNamePaulo A.G.
person.givenNameLuís M.R.
person.givenNameLuísa
person.identifier1339117
person.identifier.ciencia-id0519-449D-6F13
person.identifier.ciencia-id401E-2FEC-8303
person.identifier.ciencia-id 5C16-CCB5-F4F3
person.identifier.orcid0000-0003-2834-0501
person.identifier.orcid0000-0002-2385-4282
person.identifier.orcid0000-0003-0599-1280
person.identifier.ridB-4866-2008
person.identifier.ridF-2269-2010
person.identifier.scopus-author-id6506406159
person.identifier.scopus-author-id8585923500
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublicationbaaee084-ab97-4c95-b636-24ab6bab0e3e
relation.isAuthorOfPublication3d08baba-b032-42c4-8244-94672c4611a1
relation.isAuthorOfPublication3c9dce7a-9ae1-4e9b-9135-75e9eeec865c
relation.isAuthorOfPublication.latestForDiscovery3c9dce7a-9ae1-4e9b-9135-75e9eeec865c

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2012_ICEM15_CD_artigo.pdf
Size:
6.88 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: