Citação: Couto, David; Fonseca, E.M.M.; Piloto, P.A.G.; Meireles, Jorge; Barreira, Luísa; Ferreira, Débora (2015) - Fire resistance of cellular wooden slabs with rectangular and circular perforations. In 6th International Conference on Mechanics and Materials in Design M2D2015. ISBN 978-989-989-98832-3-9. p. 2323-2330. Azores, Portugal
Resumo: This work presents a numerical and experimental approach in order to predict the thermal behaviour and the performance of typical cellular wooden slabs with rectangular and circular perforations when submitted to fire conditions. For this purpose a 3D numerical model was validated with different experimental tests at real scale obtained in laboratory in four cellular wooden slabs. This study was conducted in accordance with European standard (EN 1365-2, 1999) and using a fire resistance furnace which complies the requirements of European standard (EN 1363-1, 1999). The numerical temperatures show good agreement with experimental results. The numerical model can easily be adjusted for other constructive solutions, to facilitate fire safety tests, in buildings with wooden slabs used in floors or in ceilings applications.
Peer review: yes
URI: http://hdl.handle.net/10198/12824
ISBN: 978-989-989-98832-3-9
Aparece nas colecções:DMA - Publicações em Proceedings Indexadas ao ISI/Scopus

Ficheiros deste registo:
Ficheiro Descrição TamanhoFormato 
ACI41.pdf2,62 MBAdobe PDFVer/Abrir


FacebookTwitterDeliciousLinkedInDiggGoogle BookmarksMySpace
Formato BibTex MendeleyEndnote Degois 

Todos os registos no repositório estão protegidos por leis de copyright, com todos os direitos reservados.