Repository logo
 
Publication

Análise biomecânica das fraturas do fémur e avaliação do melhor implante

dc.contributor.advisorFonseca, E.M.M.
dc.contributor.advisorBarbosa, Marcos Pinotti
dc.contributor.authorFernandes, Maria Goreti Antunes
dc.date.accessioned2014-02-03T12:11:20Z
dc.date.available2014-02-03T12:11:20Z
dc.date.issued2013
dc.date.submitted2013
dc.description.abstractAs fraturas ósseas na região diafisária do fémur são lesões complexas das quais resultam, habitualmente, períodos extensos de hospitalização e de reabilitação. O recurso a hastes intramedulares bloqueadas, no que diz respeito à fixação intramedular, é um dos tratamentos possíveis deste tipo de fraturas e tem sido objeto de vários trabalhos de investigação desde o seu aparecimento. Neste sentido, o presente trabalho focou-se no desenvolvimento de uma metodologia de análise computacional de diferentes tipos de fraturas diafisárias do fémur, seguindo o tipo de tratamento utilizado no hospital Nossa Senhora das Dores - Brasil. Foi gerado um biomodelo e um modelo simplificado do conjunto osso-implante-parafusos seguida de uma análise por elementos finitos. Os resultados obtidos indicam que a introdução das hastes intramedulares em aço inoxidável ou em titânio no fémur diminuem as tensões ao longo do osso, promovendo uma maior estabilidade. O estudo efetuado permitiu identificar a zona medial do fémur como a zona crítica no que diz respeito às tensões envolvidas. Na análise comparativa das tensões com diferentes materiais, o modelo com a haste em titânio apresentou um desempenho mais homogéneo do que o modelo em aço inoxidável. O modelo simplificado apresentou resultados compatíveis com o biomodelo. Este facto possibilita que o modelo simplificado se torne uma ferramenta vantajosa na análise biomecânica das fraturas diafisárias do fémur, uma vez que não há recurso a imagens médicas.por
dc.description.abstractBone fractures in the femoral diaphysis are complex lesions that usually result in extended periods of hospitalization and rehabilitation. The use of locked intramedullary nails in intramedullary fixation is one of the possible treatments of this type of fracture and has been the subject of several researches since its appearance. The present work focused on developing a methodology for computational analysis of different types of femoral diaphysis fractures, according the type of treatment at Nossa Senhora das Dores – Brazil hospital. It was created a biomodel and a simplified model of the boneimplant screws followed by a finite element analysis. The results indicate that the introduction of intramedullary nails of stainless steel or titanium into the femur reduce the stresses along the bone, providing a greater stability. The study identifies the femur medial zone as the critical region related to the stresses that are involved. The comparative analysis of strains with different materials suggests that the model in titanium was more homogenous than the model in stainless steel. The simplified model showed consistent results with the biomodel. This fact allows that the simplified model becomes an advantageous tool in biomechanical analysis of the femoral diaphysis fractures because the analysis may be unprovided with medical images.por
dc.identifier.tid201454530
dc.identifier.urihttp://hdl.handle.net/10198/9272
dc.language.isoporpor
dc.subjectFémurpor
dc.subjectFraturapor
dc.subjectHaste intramedular bloqueadapor
dc.subjectElementos finitospor
dc.subjectBiomecânicapor
dc.titleAnálise biomecânica das fraturas do fémur e avaliação do melhor implantepor
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspor
rcaap.typemasterThesispor
thesis.degree.levelMestrepor
thesis.degree.nameMestrado em Tecnologia Biomédicapor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Fernandes_Maria.pdf
Size:
2.76 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.73 KB
Format:
Item-specific license agreed upon to submission
Description: