Non-loadbearing light steel framing walls under fire

dc.contributor.authorKhetata, Mohamed S.
dc.contributor.authorPiloto, P.A.G.
dc.contributor.authorRamos Gavilán, Ana Belén
dc.date.accessioned2020-04-16T09:47:19Z
dc.date.available2020-04-16T09:47:19Z
dc.date.issued2019
dc.description.abstractThe light steel frame (LSF) construction technology started to be widely used in different types of buildings, replacing the traditional construction methods due to its light weight characteristics. Steel is recycled, dimensional stable, and ease of installation. LSF and prefabricated panels are widely used in non-loadbearing walls. The LSF walls are usually made with studs and tracks that require fire protection, normally achieved by a single plasterboard, by composite plates, or by insulation of the cavity. The partition walls are fire rated for the integrity (E) and insulation (I). The insulation capacity (I) is the ability of the element of construction to withstand fire exposure by side, without the transmission of significant heat to the unexposed side. Six fire tests were developed to define the fire resistance according to EN1363-1 [1] and EN1364-1 [2], with the main objective to evaluate the influence of the protection layers and the influence of the cavity insulation material. Numerical models are also validated with experimental tests.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationKhetata, Seddik M.; Piloto, P.A.G.; Gavilán, Ana B.R. (2019). Non-loadbearing light steel framing walls under fire. In 5th Iberian-Latin-American Congress on Fire Safety – CILASCI 5. Porto. p. 169-185. ISBN 978-989-97210-3-6pt_PT
dc.identifier.isbn978-989-97210-3-6
dc.identifier.urihttp://hdl.handle.net/10198/21682
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherALBRASCI (Luso Brazilian Association for Fire Safety)pt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectFire testspt_PT
dc.subjectLSF wallspt_PT
dc.subjectNumerical simulationpt_PT
dc.subjectFire resistancept_PT
dc.titleNon-loadbearing light steel framing walls under firept_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlacePortopt_PT
oaire.citation.endPage185pt_PT
oaire.citation.startPage169pt_PT
oaire.citation.title5th IBERIAN-LATIN-AMERICAN CONGRESS ON FIRE SAFETY – CILASCI 5pt_PT
person.familyNamePiloto
person.givenNamePaulo
person.identifier.ciencia-id0519-449D-6F13
person.identifier.orcid0000-0003-2834-0501
person.identifier.ridB-4866-2008
person.identifier.scopus-author-id6506406159
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublicationbaaee084-ab97-4c95-b636-24ab6bab0e3e
relation.isAuthorOfPublication.latestForDiscoverybaaee084-ab97-4c95-b636-24ab6bab0e3e

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
REF_235_2019_FULL_PAPERS_PROCEEDINGS_PP_169_185.pdf
Size:
5.66 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: