Publicação
Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat: Implications for Velocity-Based Training
| datacite.subject.fos | Ciências Médicas::Ciências da Saúde | |
| datacite.subject.fos | Ciências Sociais::Outras Ciências Sociais | |
| datacite.subject.sdg | 04:Educação de Qualidade | |
| datacite.subject.sdg | 03:Saúde de Qualidade | |
| dc.contributor.author | Montoro-Bombú, Raynier | |
| dc.contributor.author | Costa, Armando | |
| dc.contributor.author | Sousa, Paulo Malico | |
| dc.contributor.author | Pinheiro, Valter | |
| dc.contributor.author | Forte, Pedro | |
| dc.contributor.author | Monteiro, Luis | |
| dc.contributor.author | Ribeiro, Alex S. | |
| dc.contributor.author | Rama, Luis | |
| dc.date.accessioned | 2025-10-06T13:01:40Z | |
| dc.date.available | 2025-10-06T13:01:40Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Selecting the right linear position transducer (LPT) for velocity-based training monitoring sometimes presents uncertainties for coaches. Objectives: This study rigorously examined the test-retest reliability of three LPT–Cs using a simultaneous triangulation method of the same device during bench press (BP) and back squat (SQ) exercises performed on a Smith machine. Methods: Forty university students—13 females (23 ± 2 years) and 27 males (31.5 ± 6 years)—voluntarily participated in a randomized repeated-measures study. LPTs were randomly assigned numbers and placed at 5 cm apart to measure and collect bar displacement (∆S), mean propulsive velocity (MPV), peak velocity (PV), and time to peak velocity (T–PV). Each volunteer performed three BP and SQ attempts with pre-standardized loads (males: BP ≥ 40 kg and SQ ≥ 60 kg; females: BP ≥ 25 kg and SQ ≥ 40 kg). Results: The main findings of this study support a high degree of reliability for LPTs. For all variables, the absolute reliability presented significant values (p ≤ 0.05), with an intraclass correlation coefficient ≥ 0.995, a 95% confidence interval between 0.992–0.999, a coefficient of variation ≤ 10%, and a standard error of the mean ≤ 0.031. Conclusions: Scientists and coaches can use the LPT device as a reliable tool for monitoring velocity-based training by providing rigorous measurements of ∆S, MPV, PV, and T–PV during BP and SQ exercises. In addition, the smallest real difference reported may be useful in identifying minimal changes in ∆S within a single set (BP = 0.10 cm; SQ = 0.13 cm). | eng |
| dc.description.sponsorship | This research received no external funding | |
| dc.identifier.citation | Montoro-Bombú, Raynier; Costa, Armando; Sousa, Paulo Malico; Pinheiro, Valter; Forte, Pedro; Monteiro, Luis; Ribeiro, Alex S.; Rama, Luis (2025). Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat: Implications for Velocity-Based Training. Journal of Functional Morphology and Kinesiology. ISSN 2411-5142. 10:2, p. 1-14 | |
| dc.identifier.doi | 10.3390/jfmk10020109 | |
| dc.identifier.issn | 2411-5142 | |
| dc.identifier.uri | http://hdl.handle.net/10198/34785 | |
| dc.language.iso | eng | |
| dc.peerreviewed | yes | |
| dc.publisher | MDPI | |
| dc.relation.ispartof | Journal of Functional Morphology and Kinesiology | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nd/4.0/ | |
| dc.subject | Biomechanics | |
| dc.subject | Velocity-based training | |
| dc.subject | Force | |
| dc.subject | Monitoring training and testing | |
| dc.subject | Strength | |
| dc.subject | Performance | |
| dc.title | Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat: Implications for Velocity-Based Training | eng |
| dc.type | journal article | |
| dspace.entity.type | Publication | |
| oaire.citation.endPage | 14 | |
| oaire.citation.issue | 2 | |
| oaire.citation.startPage | 1 | |
| oaire.citation.title | Journal of Functional Morphology and Kinesiology | |
| oaire.citation.volume | 10 | |
| oaire.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| person.familyName | Forte | |
| person.givenName | Pedro | |
| person.identifier.ciencia-id | 351B-B16B-79C7 | |
| person.identifier.orcid | 0000-0003-0184-6780 | |
| relation.isAuthorOfPublication | 3ecc6d1b-07a4-40d7-81f4-df6fd7b3d5b0 | |
| relation.isAuthorOfPublication.latestForDiscovery | 3ecc6d1b-07a4-40d7-81f4-df6fd7b3d5b0 |
Ficheiros
Principais
1 - 1 de 1
A carregar...
- Nome:
- Reliability and Accuracy of Linear Position Transducers During the Bench Press and Back Squat.pdf
- Tamanho:
- 12.12 MB
- Formato:
- Adobe Portable Document Format
Licença
1 - 1 de 1
Miniatura indisponível
- Nome:
- license.txt
- Tamanho:
- 1.75 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
