Logo do repositório
 
Publicação

Biomedical applications and 3D rapid prototyping

dc.contributor.authorFonseca, E.M.M.
dc.contributor.authorTeixeira, M.C.M.
dc.date.accessioned2013-10-10T09:45:25Z
dc.date.available2013-10-10T09:45:25Z
dc.date.issued2012
dc.description.abstractThe main objective of this paper was to assess the cortical bone thickness of human lumbar vertebra, through Computed Tomography (CT) images by using both image processing software and rapid prototyping (RP) experimental methodologies. The study here presented focus sixteen postmenopausal patients from the North of Portugal, with age between 50 and 85 years, collected from May to June 2011. All clinical data were obtained in a Medical Centre of Radiology and Imaging, in Porto. Results regarding cortical bone thickness and biomechanical resistance of human lumbar vertebra are presented. The acquirement of accurate values concerning cortical bone thickness could improve the prediction of fracture risk.
dc.identifier.citationFonseca, E.M.M.; Teixeira, M.C.M. (2012). Biomedical applications and 3D rapid prototyping. In Gomes, J.F. Silva; Vaz, Mário A. P. (eds.). Experimental mechanics new trends and perspectives. Porto: Edições Inegi. p.926-942. ISBN 978-072-88260-22-2por
dc.identifier.isbn978-072-88260-22-2
dc.identifier.urihttp://hdl.handle.net/10198/8888
dc.language.isoengpor
dc.peerreviewedyespor
dc.titleBiomedical applications and 3D rapid prototypingpor
dc.typebook part
dspace.entity.typePublication
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FEME-MFE%2F102974%2F2008/PT
oaire.citation.conferencePlacePortopor
oaire.citation.endPage942por
oaire.citation.startPage926por
oaire.citation.titleExperimental mechanics new trends and perspectivespor
oaire.fundingStream5876-PPCDTI
person.familyNameFonseca
person.givenNameElza M. M.
person.identifierR-000-4MB
person.identifier.ciencia-idEB17-92E5-8374
person.identifier.orcid0000-0003-1854-6514
person.identifier.ridD-4604-2011
person.identifier.scopus-author-id7102526169
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspor
rcaap.typebookPartpor
relation.isAuthorOfPublicationbff18bdf-825b-4b45-9774-4f9d94cbe33e
relation.isAuthorOfPublication.latestForDiscoverybff18bdf-825b-4b45-9774-4f9d94cbe33e
relation.isProjectOfPublication7d1c6dfe-46c1-48e4-8068-b89321d8138d
relation.isProjectOfPublication.latestForDiscovery7d1c6dfe-46c1-48e4-8068-b89321d8138d

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
CL4.pdf
Tamanho:
6.51 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: