dc.description.abstractThis work investigates the behaviour of Double stud Light Steel Frame (LSF) walls under ISO834 standard fire through a series of experimental tests. The walls were covered on both sides with one or two fire-resistant gypsum plasterboards (Type F), and the cavity of the steel frame was either empty, partially or fully insulated with ceramic fibre. The fire resistance of the assemblies is improved due to the existence of a wider cavity, the employment of additional gypsum plasterboard layers and the use of ceramic fibre cavity insulation. In partially insulated assemblies, significantly higher fire resistance is achieved when the ceramic fibre is placed towards the fire-exposed gypsum plasterboard. Moreover, the number of studs in contact with the unexposed gypsum plasterboard affects the fire resistance of the specimens. The experimental data acquired is useful to conduct further numerical analyses and experimental studies, as well as to understand the unique thermal behaviour of different configurations of double stud LSF walls at elevated temperatures.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationAlves, Matheus; Piloto, P.A.G.; Aiko Kimura, Erica F.; Constantini, Giada; Ianni, Alessandro; Meda, Alberto (2022). Fire behaviour of non-load bearing double stud cold-formed steel frame walls. Mecânica Experimental. ISSN 1646-7078. p. 27-37pt_PT
dc.identifier.issn1646-7078
dc.identifier.urihttp://hdl.handle.net/10198/27519
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherAPAETpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectFire resistancept_PT
dc.subjectDouble stud LSF wallspt_PT
dc.subjectExperimental testspt_PT
dc.subjectCeramic fibrept_PT
dc.titleFire behaviour of non-load bearing double stud cold-formed steel frame wallspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceLisboapt_PT
oaire.citation.endPage37pt_PT
oaire.citation.issue35pt_PT
oaire.citation.startPage27pt_PT
oaire.citation.titleMECÂNICA EXPERIMENTALpt_PT
person.familyNameAlves
person.familyNamePiloto
person.givenNameMatheus Henrique
person.givenNamePaulo A.G.
person.identifier.ciencia-idDA1E-F1FC-B91E
person.identifier.ciencia-id0519-449D-6F13
person.identifier.orcid0000-0001-8139-6761
person.identifier.orcid0000-0003-2834-0501
person.identifier.ridB-4866-2008
person.identifier.scopus-author-id6506406159
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublication589186bc-1902-41dc-b4ff-d6359a028987
relation.isAuthorOfPublicationbaaee084-ab97-4c95-b636-24ab6bab0e3e
relation.isAuthorOfPublication.latestForDiscoverybaaee084-ab97-4c95-b636-24ab6bab0e3e

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
REF_303.pdf
Size:
9.27 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: