Repository logo
 
Publication

Pure-tone audiogram: measuring auditory sensitivity over the age

dc.contributor.authorTeixeira, João Paulo
dc.contributor.authorFernandes, Paula Odete
dc.date.accessioned2014-06-20T10:38:39Z
dc.date.available2014-06-20T10:38:39Z
dc.date.issued2013
dc.description.abstractIn this study a pure tone audiogram was developed under the Matlab® mathematical software. Audiogram measurements were performed to 35 subjects belonging to the female and male and aged between 10 and 88 years old. Some of the subjects with more advanced age had hearing problems over the course of age, however, none of them was carrying any type of hearing aid. The threshold of the Sound Pressure Level (SPL) was recorded under 12 pure tones between 125 Hz and 15 kHz. The developed pure-tone audiogram confirmed its ability to produce auditory brainstem responses (ABRs). Statistical analysis of the SPL threshold shows no differences between genders and confirms the correlation between age and loss of sensitivity, more accentuated for higher frequency tones. A strong loss of sensitivity was observed after the decade of 60 years old.por
dc.identifier.citationTeixeira, João Paulo; Fernandes, Paula O. (2013). Pure-tone audiogram: measuring auditory sensitivity over the age. In 6th International Joint Conference on Biomedical Engineering Systems and Technologies. Barcelonapor
dc.identifier.urihttp://hdl.handle.net/10198/9709
dc.language.isoengpor
dc.peerreviewedyespor
dc.subjectPure-tone audiogrampor
dc.subjectHearing sensitivitypor
dc.subjectEarpor
dc.titlePure-tone audiogram: measuring auditory sensitivity over the agepor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceBarcelonapor
oaire.citation.title6th International Joint Conference on Biomedical Engineering Systems and Technologiespor
person.familyNameTeixeira
person.familyNameFernandes
person.givenNameJoão Paulo
person.givenNamePaula Odete
person.identifier663194
person.identifierN-3804-2013
person.identifier.ciencia-id4F15-B322-59B4
person.identifier.ciencia-id991D-9D1E-D67D
person.identifier.orcid0000-0002-6679-5702
person.identifier.orcid0000-0001-8714-4901
person.identifier.ridN-6576-2013
person.identifier.scopus-author-id57069567500
person.identifier.scopus-author-id35200741800
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublication33f4af65-7ddf-46f0-8b44-a7470a8ba2bf
relation.isAuthorOfPublication2269147c-2b53-4d1c-bc1b-f1367d197262
relation.isAuthorOfPublication.latestForDiscovery2269147c-2b53-4d1c-bc1b-f1367d197262

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
BIODEVICES.pdf
Size:
611.63 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: