Logo do repositório
 
Publicação

Fire after earthquake assessment of 3D reinforced concrete structures

datacite.subject.fosEngenharia e Tecnologia
datacite.subject.fosEngenharia e Tecnologia::Engenharia Civil
datacite.subject.sdg09:Indústria, Inovação e Infraestruturas
dc.contributor.authorIsmail Haouach
dc.contributor.authorAbdelhak Kada
dc.contributor.authorBelkacem Lamri
dc.contributor.authorPiloto, Paulo A.G.
dc.date.accessioned2026-03-24T10:25:01Z
dc.date.available2026-03-24T10:25:01Z
dc.date.issued2024
dc.description.abstractDespite that, an earthquake’s occurrence can lead to dramatic effects with significant damage in urban areas, including human and material losses. Fire after an earthquake amplifies the overall impact and becomes a catastrophic event. Most constructions in Algeria are made of reinforced concrete, and current regulations overlook fires after earthquakes. Structural designs are inadequate to handle such events. This study aims to investigate the behaviour of 3D reinforced concrete frames, as part of a residential building, designed according to internal codes, CBA93 and RPA99 v2003. This 3D RC structure is exposed to several load levels of its vertical load bearing capacity. The structural system is assumed to undergo seismic scenarios characterised by various levels of story drift and damage level types. The structure is then exposed to the standard fire ISO834 model. Numerical investigations are carried out for thermo-mechanical analysis using the finite element software ANSYS, taking into account geometric and material non-linearities. Results highlight the significant impact of vertical loads, story drifts, fire scenarios, and structural damage on a building’s response to fire following an earthquake. These factors collectively influence the collapse probabilities, underlining the importance of holistic risk assessment in structural design.eng
dc.identifier.citationHaouach, Ismail; Kada, Abdelhak; Lamri, Belkacem; Piloto, Paulo A.G. (2024). Fire after earthquake assessment of 3D reinforced concrete structures. Engineering Structures. ISSN 0141-0296. 319, p. 1-21. DOI: 10.1016/j.engstruct.2024.118889.
dc.identifier.doi10.1016/j.engstruct.2024.118889
dc.identifier.issn0141-0296
dc.identifier.urihttp://hdl.handle.net/10198/36245
dc.language.isoeng
dc.peerreviewedyes
dc.publisherElsevier BV
dc.relation.hasversionhttps://www.sciencedirect.com/science/article/pii/S0141029624014512?via%3Dihub
dc.relation.ispartofEngineering Structures
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectFire
dc.subjectEarthquake
dc.subjectComputational Mechanics
dc.subjectConcrete Structures
dc.titleFire after earthquake assessment of 3D reinforced concrete structures
dc.typejournal article
dspace.entity.typePublication
oaire.citation.startPage118889
oaire.citation.titleEngineering Structures
oaire.citation.volume319
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
person.familyNamePiloto
person.givenNamePaulo A.G.
person.identifier.ciencia-id0519-449D-6F13
person.identifier.orcid0000-0003-2834-0501
person.identifier.ridB-4866-2008
person.identifier.scopus-author-id6506406159
relation.isAuthorOfPublicationbaaee084-ab97-4c95-b636-24ab6bab0e3e
relation.isAuthorOfPublication.latestForDiscoverybaaee084-ab97-4c95-b636-24ab6bab0e3e

Ficheiros

Principais
A mostrar 1 - 1 de 1
A carregar...
Miniatura
Nome:
REF_328.pdf
Tamanho:
11.61 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.75 KB
Formato:
Item-specific license agreed upon to submission
Descrição: