Repository logo
 
Publication

A wireless acquisition system for monitoring the influence of loads on vertebral column behaviour

dc.contributor.authorRibeiro, J.E.
dc.contributor.authorCarmo, João Paulo
dc.date.accessioned2010-02-11T17:25:38Z
dc.date.available2010-02-11T17:25:38Z
dc.date.issued2008
dc.description.abstractThis paper presents a wireless acquisition module (WAM). This allows the monitoring of heavy loads influence on vertebral column’s behaviour. Each module makes the electromyography (EMG), to measure the electric potentials on the iliocostalis and longissimus thoracis muscles, and use a dual-axis accelerometer to get the movements of the body, in order to obtain the complete behaviour of the vertebral column. The solution chosen to transmit the body’s measured signals for further processing, is a wireless link working in the 433 MHz ISM band. The acquired information is transmitted with a maximum rate of 40 kbps, a resolution of 9.8 V, and accommodates two analog channels. An analog channel with differential input connected to the electrodes, is used to measure the EMG signal, while the remained channel is used in the patient’s movements measurements. The dimensions of the proposed acquisition system are about 7×5×2 cm, and will help to understand the influence of heavy loads as a risk factors in the vertebral column, such as the scoliosis and lordosis.pt
dc.identifier.citationRibeiro, J.E.; Carmo, João (2008). A wireless acquisition system for monitoring the influence of loads on vertebral column behaviour. In 1st International Conference on Biomedical Electronics and Devices. Funchal. p.233-237. ISBN 978-989-8111- 17-3pt
dc.identifier.isbn978-989-8111- 17-3
dc.identifier.urihttp://hdl.handle.net/10198/1854
dc.language.isoengpt
dc.publisherSpringerpt
dc.subjectBiotelemetrypt
dc.subjectBiomechanicalpt
dc.subjectWireless electromyographypt
dc.titleA wireless acquisition system for monitoring the influence of loads on vertebral column behaviourpt
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceFunchalpt
oaire.citation.endPage237pt
oaire.citation.startPage233pt
oaire.citation.titleBIODEVICES 2008: First International Conference on Biomedical Electronics and Devicespt
person.familyNameRibeiro
person.givenNameJ.E.
person.identifierR-000-6Y8
person.identifier.ciencia-id0F15-FB62-29DB
person.identifier.orcid0000-0001-6300-148X
person.identifier.ridG-3839-2018
person.identifier.scopus-author-id25638652400
rcaap.rightsopenAccesspt
rcaap.typeconferenceObjectpt
relation.isAuthorOfPublicationc90169e6-7889-4270-a096-35b98c75f9f9
relation.isAuthorOfPublication.latestForDiscoveryc90169e6-7889-4270-a096-35b98c75f9f9

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
C1_094.pdf
Size:
76.07 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.83 KB
Format:
Item-specific license agreed upon to submission
Description: