Repository logo
 
Publication

Control of grid-connected inverter output current: a practical review

dc.contributor.authorAvila, Victor Habermann
dc.contributor.authorLeite, Vicente
dc.date.accessioned2022-01-12T14:54:33Z
dc.date.available2022-01-12T14:54:33Z
dc.date.issued2020
dc.description.abstractThe number of grid-connected inverters is growing due to the expansion of the use of renewable energies (RE) systems and this may affect grid power quality and stability. Some control algorithms reduce injected current harmonics and add new possibilities to the converter. This paper implements and analyses the proportional integral (PI) controller in the synchronous frame and the proportional resonant (PR) controller with and without the harmonics compensators (HC). All these control strategies have proven to be effective and robust. However, the PR+HC controller presents better output current quality. The PI and PR controllers have similar performances. This work also compares the harmonic content of the current with the IEEE 1547 reference and with three commercial inverters from different manufacturers.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationAvila, Victor Habermann; Leite, Vicente (2020). Control of grid-connected inverter output current: a practical review. . In 9th International Conference on Renewable Energy Research and Applications. Glasgow. p. 232-235. ISBN 978-1-7281-7369-6pt_PT
dc.identifier.doi10.1109/ICRERA49962.2020.9242710pt_PT
dc.identifier.isbn978-1-7281-7369-6
dc.identifier.urihttp://hdl.handle.net/10198/24586
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectGrid-connected inverterpt_PT
dc.subjectProportional resonantpt_PT
dc.subjectSynchronous framept_PT
dc.subjectCurrent controlpt_PT
dc.titleControl of grid-connected inverter output current: a practical reviewpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.endPage235pt_PT
oaire.citation.startPage232pt_PT
person.familyNameLeite
person.givenNameVicente
person.identifier.ciencia-id781B-C2C2-44B3
person.identifier.orcid0000-0002-8790-519X
person.identifier.ridN-6962-2013
person.identifier.scopus-author-id36456604300
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublicationf7100300-5afd-4ace-92ce-4243952efcce
relation.isAuthorOfPublication.latestForDiscoveryf7100300-5afd-4ace-92ce-4243952efcce

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Control_of_grid-connected_inverter_output_current_a_practical_review.pdf
Size:
4.94 MB
Format:
Adobe Portable Document Format