Publication
Accuracy of Jitter and Shimmer Measurements
dc.contributor.author | Teixeira, João Paulo | |
dc.contributor.author | Gonçalves, André Amorim | |
dc.date.accessioned | 2018-04-09T16:28:08Z | |
dc.date.available | 2018-04-09T16:28:08Z | |
dc.date.issued | 2014 | |
dc.description.abstract | A synthesized speech signal was used to measure the accuracy of the Jitter and Shimmer parameters calculated by a previously presented algorithm. The formant model of speech synthesis was used to produce speech signals with a controlled glottal periods and magnitudes according to previously determined Jitter and Shimmer parameters values. The Jitter parameters (jitta, jitter, rap and ppq5) and the Shimmer parameters (ShdB, Shim, apq3 and apq5) were calculated with a previously developed algorithm and compared with the analytic determined values and also with measures made with Praat software. Experiments with different type of jitter and shimmer perturbations and with different F0 values were conducted. Also the influence of F0 variations on Shimmer and Jitter measures was experimented. | pt_PT |
dc.description.version | info:eu-repo/semantics/publishedVersion | pt_PT |
dc.identifier.citation | Teixeira, João Paulo; Gonçalves, André (2014). Accuracy of Jitter and Shimmer Measurements. In Procedia Technology e CENTERIS 2014 - Conference on ENTERprise Information Systems / ProjMAN 2014 - International Conference on Project MANagement / HCIST 2014 - International Conference on Health and Social Care Information Systems and Technologies. Troia | pt_PT |
dc.identifier.doi | 10.1016/j.protcy.2014.10.134 | pt_PT |
dc.identifier.uri | http://hdl.handle.net/10198/16843 | |
dc.language.iso | eng | pt_PT |
dc.peerreviewed | yes | pt_PT |
dc.publisher | Elsevier | pt_PT |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | pt_PT |
dc.title | Accuracy of Jitter and Shimmer Measurements | pt_PT |
dc.type | conference object | |
dspace.entity.type | Publication | |
oaire.citation.endPage | 1199 | pt_PT |
oaire.citation.startPage | 1190 | pt_PT |
oaire.citation.title | Procedia Technology e CENTERIS 2014 - Conference on ENTERprise Information Systems / ProjMAN 2014 - International Conference on Project MANagement / HCIST 2014 - International Conference on Health and Social Care Information Systems and Technologies. | pt_PT |
oaire.citation.volume | 16 | pt_PT |
person.familyName | Teixeira | |
person.givenName | João Paulo | |
person.identifier | 663194 | |
person.identifier.ciencia-id | 4F15-B322-59B4 | |
person.identifier.orcid | 0000-0002-6679-5702 | |
person.identifier.rid | N-6576-2013 | |
person.identifier.scopus-author-id | 57069567500 | |
rcaap.rights | restrictedAccess | pt_PT |
rcaap.type | conferenceObject | pt_PT |
relation.isAuthorOfPublication | 33f4af65-7ddf-46f0-8b44-a7470a8ba2bf | |
relation.isAuthorOfPublication.latestForDiscovery | 33f4af65-7ddf-46f0-8b44-a7470a8ba2bf |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Accuracy Jitter and Shimmer Measurements_publicado.pdf
- Size:
- 364.99 KB
- Format:
- Adobe Portable Document Format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.75 KB
- Format:
- Item-specific license agreed upon to submission
- Description: