Repository logo
 
Publication

Fully-automated “timed Up and go” and “30-second chair stand” tests assessment: a low cost approach based on arduino and LabVIEW

dc.contributor.authorGonçalves, José
dc.contributor.authorBatista, José
dc.contributor.authorNovo, André
dc.date.accessioned2017-07-28T13:20:47Z
dc.date.available2017-07-28T13:20:47Z
dc.date.issued2015
dc.description.abstractIn this paper it is described the prototyping of an instrumented chair that allows to fully-automate the ``Timed Up and Go'' and ``30-Second Chair Stand'' tests assessment. The presented functional chair prototype is a low cost approach that uses inexpensive sensors and the Arduino platform as the data acquisition board, with its software developed resorting to LabVIEW. The ``Timed up and go test'' consists in measuring the time spent in the task execution of standing up from a chair, walk three meters with a maximum speed without running, turn a cone and going back to the initial position. The ``30-Second Chair Stand'' test consists in the count of the number of completed chair stands in 30 seconds. It are agility and strength tests easy to setup and execute although they lack of repeatability, whenever the measures are taken manually, due to the rough errors that are introduced.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationGonçalves, José; Batista, José; Novo, André (2015). Fully-automated “timed Up and go” and “30-second chair stand” tests assessment: a low cost approach based on arduino and LabVIEW. In 11th Portuguese Conference on Automatic Control. Porto. ISSN 18761100. 321, p.669-678pt_PT
dc.identifier.doi10.1007/978-3-319-10380-8_64pt_PT
dc.identifier.issn18761100
dc.identifier.urihttp://hdl.handle.net/10198/14380
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectArduinopt_PT
dc.subjectSensorspt_PT
dc.subjectTimed up and go testpt_PT
dc.subject30-Second chair stand testpt_PT
dc.titleFully-automated “timed Up and go” and “30-second chair stand” tests assessment: a low cost approach based on arduino and LabVIEWpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlacePortopt_PT
oaire.citation.endPage678pt_PT
oaire.citation.startPage669pt_PT
oaire.citation.title11th Portuguese Conference on Automatic Controlpt_PT
oaire.citation.volume321pt_PT
person.familyNameGonçalves
person.familyNameBatista
person.familyNameNovo
person.givenNameJosé
person.givenNameJosé
person.givenNameAndré
person.identifierR-000-7ZW
person.identifierH-1386-2012
person.identifier.ciencia-id8112-DCE2-D025
person.identifier.ciencia-id7D14-8584-AB2B
person.identifier.orcid0000-0002-5499-1730
person.identifier.orcid0000-0003-0344-3336
person.identifier.orcid0000-0001-8583-0406
person.identifier.ridB-8547-2018
person.identifier.scopus-author-id48361230200
person.identifier.scopus-author-id20435350700
person.identifier.scopus-author-id612710
rcaap.rightsrestrictedAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublication6a3b0b39-7fe9-4450-94f4-ced3941947da
relation.isAuthorOfPublication9e14e4a0-3d7a-42e8-8021-52e336b12de6
relation.isAuthorOfPublicationf17cfa22-2a97-4396-bdc6-4570baee6885
relation.isAuthorOfPublication.latestForDiscovery6a3b0b39-7fe9-4450-94f4-ced3941947da

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
FinalProceedings C2014 Cadeira.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: