Repository logo
 
No Thumbnail Available
Publication

Fire resistance of non-loadbearing LSF walls

Use this identifier to reference this record.
Name:Description:Size:Format: 
Silva_Luiz.pdf17.55 MBAdobe PDF Download

Abstract(s)

The present work presents a study across the effects of fire in nonloadbering Light- Steel Frame (LSF) walls. Eight experimental tests and twenty-two parametric analyses were performed to evaluate the influence the thickness of the cavity, the thickness of the structural steel, the effect of the protection layer and the influence of insulation material in the cavity. The thickness of the protection layer presents the bigger influence in fire resistance, followed by the effect of the insulation material in the cavity. Four configurations of protection layers and three different LSF structures were evaluated, and a test with insulation in the cavities.
Este trabalho apresenta um estudo acerca dos efeitos de incêndios em estruturas de Light-Steel Frame (LSF) com paredes não portantes. Foram realizados oito ensaios experimentais e vinte e duas análises paramétricas para avaliar a influência da espessura da cavidade, espessura do aço da estrutura, efeito da camada protetora e influência do material isolante na cavidade. Dentre os fatores analisados, conclui-se que a espessura da camada protetora tem a maior influencia na resistência ao fogo, seguido pelo efeito do material isolante nas cavidades. Quatro camadas protetoras e três estruturas foram analisadas, além de um teste com isolante na cavidade.

Description

Dupla diplomação com a Universidade Tecnológica e Federal do Paraná

Keywords

LSF walls Fire resistance Ansys fluent Ansys multiphysics Experimental tests

Pedagogical Context

Citation

Research Projects

Organizational Units

Journal Issue