This work investigates the impact of fire in non-loadbearing Light Steel Frame (LSF) walls. Numerical validation and a set of parametric analyses are carried out using ANSYS Multiphysics software in order to show the impact of structural stud’s space, cavity thickness, the effect of the protective layer, and the effect of insulating material in the cavity. The results show that the cavity insulation has the greatest influence on fire resistance, followed by the increase of the number of gypsum plasterboards of the protection layer. Also the decreasing of the studs spacing has improved the time of the resistance of walls under fire.
Ce travail étudie l'impact du feu dans les murs non porteurs à ossature légère en acier (LSF). Une validation numérique et un ensemble d'analyses paramétriques sont réalisés à l'aide du logiciel ANSYS®Multiphysics afin de montrer l'impact de l'espace du montant structurel, de l'épaisseur de la cavité, de l'effet de la couche protectrice et de l'effet du matériau isolant dans la cavité. Les résultats montrent que l'isolation de la cavité a la plus grande influence sur la résistance au feu, suivie par l'augmentation du nombre de plaques de plâtre de la couche de protection et aussi la diminution de l'espacement entre les montants a amélioré la durée de la résistance des murs sous le feu.

Description

Mestrado de dupla diplomação com a Université Libre de Tunis

Keywords

Fire resistance LSF walls Insulation Finite element method Experimental tests

Pedagogical Context

Citation

Research Projects

Organizational Units

Journal Issue