Publication 
Laminar blood flow in stenotic microchannels
| dc.contributor.author | Calejo, Joana A.C. | |
| dc.contributor.author | Garcia, Valdemar | |
| dc.contributor.author | Fernandes, Carla S. | |
| dc.date.accessioned | 2015-12-14T10:16:58Z | |
| dc.date.available | 2015-12-14T10:16:58Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | In this work, Newtonian and non-Newtonian laminar blood flow in rectangular microchannels with symmetric and asymmetric atheroma were numerically studied. It was observed that the impact of symmetry of the atheroma is almost negligible and the non-Newtonian properties of blood leads to higher pressure drops and wall shear stresses than the ones obtained for Newtonian flows. | pt_PT | 
| dc.description.sponsorship | The authors acknowledge the financial support provided by: EXPL/EMS-SIS/2215/2013 and PTDC/SAU-ENB/116929/2010 from FCT (Science and Technology Foundation), COMPETE, QREN and FEDER. | |
| dc.identifier.citation | Calejo, Joana A. C.; Garcia, Valdemar; Fernandes, Carla S. (2015). Laminar blood flow in stenotic microchannels. In Proceeding of IBEREO2015. Coimbra, Portuga. p. 299-302. ISBN 978-989-26-1056-6 | pt_PT | 
| dc.identifier.isbn | 978-989-26-1056-6 | |
| dc.identifier.uri | http://hdl.handle.net/10198/12508 | |
| dc.language.iso | eng | pt_PT | 
| dc.peerreviewed | yes | pt_PT | 
| dc.relation | MicroBloodSystems - Blood rheology and blood cell migration in microfluidic systems | |
| dc.relation | BIOMIMETIC - A biomimetic microdevice for the diagnosis of erythrocytes diseases based on their deformability | |
| dc.rights.uri | http://creativecommons.org/licenses/by/4.0/ | pt_PT | 
| dc.subject | Microchannel | pt_PT | 
| dc.subject | Atheroma | pt_PT | 
| dc.subject | Computational fluid dynamics | pt_PT | 
| dc.subject | Wall shear stress | pt_PT | 
| dc.subject | Pressure drop | pt_PT | 
| dc.title | Laminar blood flow in stenotic microchannels | pt_PT | 
| dc.type | conference paper | |
| dspace.entity.type | Publication | |
| oaire.awardTitle | MicroBloodSystems - Blood rheology and blood cell migration in microfluidic systems | |
| oaire.awardTitle | BIOMIMETIC - A biomimetic microdevice for the diagnosis of erythrocytes diseases based on their deformability | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/EXPL%2FEMS-SIS%2F2215%2F2013/PT | |
| oaire.awardURI | info:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FSAU-ENB%2F116929%2F2010/PT | |
| oaire.citation.conferencePlace | Coimbra | pt_PT | 
| oaire.citation.endPage | 302 | pt_PT | 
| oaire.citation.startPage | 299 | pt_PT | 
| oaire.citation.title | IBEREO2015 | pt_PT | 
| oaire.fundingStream | 5876-PPCDTI | |
| oaire.fundingStream | 5876-PPCDTI | |
| person.familyName | Garcia | |
| person.familyName | Fernandes | |
| person.givenName | Valdemar | |
| person.givenName | Carla S. | |
| person.identifier.ciencia-id | F319-3D67-9DB7 | |
| person.identifier.orcid | 0000-0002-3941-2438 | |
| person.identifier.orcid | 0000-0002-3138-7493 | |
| person.identifier.rid | A-4269-2015 | |
| person.identifier.scopus-author-id | 8253740700 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.identifier | http://doi.org/10.13039/501100001871 | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| project.funder.name | Fundação para a Ciência e a Tecnologia | |
| rcaap.rights | openAccess | pt_PT | 
| rcaap.type | conferenceObject | pt_PT | 
| relation.isAuthorOfPublication | f9422279-4412-49c2-becd-1e696a8c5c4b | |
| relation.isAuthorOfPublication | 8f9cf139-cfef-4025-ba87-56425618bc6e | |
| relation.isAuthorOfPublication.latestForDiscovery | 8f9cf139-cfef-4025-ba87-56425618bc6e | |
| relation.isProjectOfPublication | f8938915-c19f-4bed-a45a-684e0504ed3c | |
| relation.isProjectOfPublication | 0785b517-d2cf-4d92-b2e1-d45afee17273 | |
| relation.isProjectOfPublication.latestForDiscovery | 0785b517-d2cf-4d92-b2e1-d45afee17273 | 
