Repository logo
 
Publication

Influence of bone drilling parameters on the thermal stress distribution

dc.contributor.authorFernandes, M.G.A.
dc.contributor.authorFonseca, E.M.M.
dc.contributor.authorJorge, Renato N.
dc.date.accessioned2017-01-13T16:40:52Z
dc.date.available2017-01-13T16:40:52Z
dc.date.issued2016
dc.description.abstractThe material removal through the drilling involves two important processes. The first one is the drilling of material by cutting edges of the drill bit and the second is the friction generated by the contact between the drill bit and the hole wall of the material. Both processes lead to heat generation during drilling. In clinical practice, drilling procedures with high-speed cutting tools are often applied on bone tissue. These operations are associated to complications such as thermal osteonecrosis due to the excessive heat generation and mechanical damage due to the excessive levels of penetration force. The development of additional tools for accurately simulate the drilling is essential to predict the risk of thermomechanical damage during bone drilling. This paper investigates the thermal and mechanical damage in bone tissue induced by different parameters. An experimental and numerical approach of bone drilling has been conducted. A three-dimensional dynamic numerical model was developed to predict the thermo-mechanical stress generated during the drilling. The numerical model incorporates the geometric and dynamic characteristics involved in the drilling processes, as well the developed temperature inside the material. The numerical analysis has been validated by experimental tests using polyurethane foam materials with similar mechanical properties to the human bone.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationFernandes, M.G.A.; Fonseca, E.M.M.; Jorge, Renato N. (2016). Influence of bone drilling parameters on the thermal stress distribution. In 5th International Conference on Integrity-Reliability-Failure IRF2016. Porto. p. 517-528. ISBN 978-989-98832-5-3pt_PT
dc.identifier.isbn978-989-98832-5-3
dc.identifier.urihttp://hdl.handle.net/10198/13777
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectBone drillingpt_PT
dc.subjectDamagept_PT
dc.subjectFinite element analysispt_PT
dc.subjectTemperaturept_PT
dc.titleInfluence of bone drilling parameters on the thermal stress distributionpt_PT
dc.typeconference object
dspace.entity.typePublication
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876/UID%2FEMS%2F50022%2F2013/PT
oaire.citation.conferencePlacePortopt_PT
oaire.citation.endPage528pt_PT
oaire.citation.startPage517pt_PT
oaire.citation.title5th International Conference on Integrity-Reliability-Failure IRF2016pt_PT
oaire.fundingStream5876
person.familyNameFonseca
person.givenNameElza M. M.
person.identifierR-000-4MB
person.identifier.ciencia-idEB17-92E5-8374
person.identifier.orcid0000-0003-1854-6514
person.identifier.ridD-4604-2011
person.identifier.scopus-author-id7102526169
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspt_PT
rcaap.typeconferenceObjectpt_PT
relation.isAuthorOfPublicationbff18bdf-825b-4b45-9774-4f9d94cbe33e
relation.isAuthorOfPublication.latestForDiscoverybff18bdf-825b-4b45-9774-4f9d94cbe33e
relation.isProjectOfPublication50710c88-5cb6-45f8-8a08-22b46837eed8
relation.isProjectOfPublication.latestForDiscovery50710c88-5cb6-45f8-8a08-22b46837eed8

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ACI51.pdf
Size:
2.08 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: