Logo do repositório
 
Publicação

Load bearing capacity of light timber frame walls under fire

dc.contributor.authorPiloto, P.A.G.
dc.contributor.authorFonseca, E.M.M.
dc.date.accessioned2022-05-17T15:40:55Z
dc.date.available2022-05-17T15:40:55Z
dc.date.issued2022
dc.description.abstractLight Timer Frame Walls are made of solid timber elements and are usually fire protected by other materials. This investigation determines the residual load bearing capacity of Light Timber Frame Walls for fire rating periods of 30, 60, 90 and 120 min. The timber frame is made with 3 studs and 2 tracks, using two different fire protection levels (one and two gypsum layers). The computational model includes the thermal analysis under standard fire, including all types of materials and a sequential mechanical analysis with incremental load applied for each fire rating periods, applied just for the load bearing material. Nonlinear solution methods are used with small tolerance values for solution convergence, to determine the correct temperature and displacement fields. The thermal and the mechanical properties are considered temperature dependent. The mechanical analysis considers large displacement behaviour, and the charring effect of wood is included by the reduction of the stiffness and strength of the timber. The results show that the load bearing capacity decreases with the fire exposure time. A new proposal is presented between the load bearing capacity and the fire rating and finally the char layer is compared with the current and future version of Eurocode 5, part 1.2.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationPiloto, P.A.G.; Fonseca, E.M.M. (2022). Load bearing capacity of light timber frame walls under fire. Mathematics in Computer Science. ISSN 1661-8289. 16:1, p. 1-16pt_PT
dc.identifier.doi10.1007/s11786-022-00521-ypt_PT
dc.identifier.eissn1661-8270
dc.identifier.issn1661-8289
dc.identifier.urihttp://hdl.handle.net/10198/25474
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherSpringerpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectFirept_PT
dc.subjectLTFW wallspt_PT
dc.subjectLoad bearingpt_PT
dc.subjectCharring ratept_PT
dc.subjectFinite element methodpt_PT
dc.titleLoad bearing capacity of light timber frame walls under firept_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issue1pt_PT
oaire.citation.titleMathematics in Computer Sciencept_PT
oaire.citation.volume16pt_PT
person.familyNamePiloto
person.givenNamePaulo A.G.
person.identifier.ciencia-id0519-449D-6F13
person.identifier.orcid0000-0003-2834-0501
person.identifier.ridB-4866-2008
person.identifier.scopus-author-id6506406159
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationbaaee084-ab97-4c95-b636-24ab6bab0e3e
relation.isAuthorOfPublication.latestForDiscoverybaaee084-ab97-4c95-b636-24ab6bab0e3e

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
Piloto-Fonseca2022_Article_LoadBearingCapacityOfLightTimb.pdf
Tamanho:
2.81 MB
Formato:
Adobe Portable Document Format