Repository logo
 
Publication

Cell-free layer (CFL) analysis in a glass capillary: comparison between a manual and automatic method

dc.contributor.authorBento, David
dc.contributor.authorPinho, Diana
dc.contributor.authorPereira, Ana I.
dc.contributor.authorLima, Rui A.
dc.date.accessioned2014-10-30T10:57:17Z
dc.date.available2014-10-30T10:57:17Z
dc.date.issued2011
dc.description.abstractIn this study, in vitro blood flowing through a 100 m glass capillary was studied. The images were captured using a confocal system and post-processed using Image J and MatLab. The aim of the present work, was to measure the trajectories of the cell-free layer (CFL) by using two different methods, i. e., a manual method (MM) and an automatic method (AM). For theMM we have used amanual tracking plugin (MTrackJ) from Image J to track labeled red blood cells (RBCs) flowing around the boundary of the RBCs core. For the AM we have used a MatLab scripts to measure automatically the CFL trajectories. The preliminary numerical results suggest that the CFL trajectories follow a polynomial function for both methods.por
dc.description.sponsorshipThe authors acknowledge the financial support provided by: PTDC/SAU-BEB/108728/2008, PTDC/SAU-BEB/105650/2008, PTDC/EME-MFE/099109/2008 and PTDC/SAU-ENB/116929/2010 from the FCT (Science and Technology Foundation) and COMPETE, Portugal.
dc.identifier.citationBento, David; Pinho, Diana; Pereira, Ana I.; Lima, R. (2012) . Cell-free layer (CFL) analysis in a glass capillary: comparison between a manual and automatic method. In International Conference on Numerical Analysis and Applied Mathematics. Greece. p.786-789por
dc.identifier.urihttp://hdl.handle.net/10198/11216
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherAIP Conference Proceedingspor
dc.relationANEURYSM - Hemodynamic Study in Cerebral Aneurysms
dc.relationHemo-Networks - Experimental and computational investigations of the factors influencing blood flow in microvascular networks.
dc.relationBIOMIMETIC - A biomimetic microdevice for the diagnosis of erythrocytes diseases based on their deformability
dc.subjectCell-free layerpor
dc.subjectAutomatic methodpor
dc.subjectRed blood cellspor
dc.subjectNonlinear optimizationpor
dc.titleCell-free layer (CFL) analysis in a glass capillary: comparison between a manual and automatic methodpor
dc.typeconference paper
dspace.entity.typePublication
oaire.awardTitleANEURYSM - Hemodynamic Study in Cerebral Aneurysms
oaire.awardTitleHemo-Networks - Experimental and computational investigations of the factors influencing blood flow in microvascular networks.
oaire.awardTitleBIOMIMETIC - A biomimetic microdevice for the diagnosis of erythrocytes diseases based on their deformability
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FEME-MFE%2F099109%2F2008/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FSAU-BEB%2F108728%2F2008/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FSAU-BEB%2F105650%2F2008/PT
oaire.awardURIinfo:eu-repo/grantAgreement/FCT/5876-PPCDTI/PTDC%2FSAU-ENB%2F116929%2F2010/PT
oaire.citation.conferencePlaceGreecepor
oaire.citation.endPage789por
oaire.citation.startPage786por
oaire.citation.titleInternational Conference on Numerical Analysis and Applied Mathematicspor
oaire.fundingStream5876-PPCDTI
oaire.fundingStream5876-PPCDTI
oaire.fundingStream5876-PPCDTI
oaire.fundingStream5876-PPCDTI
person.familyNamePinho
person.familyNamePereira
person.familyNameLima
person.givenNameDiana
person.givenNameAna I.
person.givenNameRui A.
person.identifier.ciencia-id5214-ED0C-35E8
person.identifier.ciencia-id0716-B7C2-93E4
person.identifier.ciencia-idEE12-C3FB-349D
person.identifier.orcid0000-0002-3884-6496
person.identifier.orcid0000-0003-3803-2043
person.identifier.orcid0000-0003-3428-637X
person.identifier.ridF-3168-2010
person.identifier.ridH-5157-2016
person.identifier.scopus-author-id15071961600
person.identifier.scopus-author-id18437397800
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.identifierhttp://doi.org/10.13039/501100001871
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
project.funder.nameFundação para a Ciência e a Tecnologia
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublication02bf2dd9-33ed-4d87-b61d-ca39c51f8451
relation.isAuthorOfPublicatione9981d62-2a2b-4fef-b75e-c2a14b0e7846
relation.isAuthorOfPublication7b50c499-8095-4f4f-8b1b-fa7388e4ff62
relation.isAuthorOfPublication.latestForDiscovery7b50c499-8095-4f4f-8b1b-fa7388e4ff62
relation.isProjectOfPublicationadd108a5-17d2-41ea-8731-e51fe8723bfe
relation.isProjectOfPublication34870e5f-cd6e-443b-91f6-12f1a7a74013
relation.isProjectOfPublication3897ce26-be5f-458d-829a-925628d3b9c7
relation.isProjectOfPublication0785b517-d2cf-4d92-b2e1-d45afee17273
relation.isProjectOfPublication.latestForDiscovery34870e5f-cd6e-443b-91f6-12f1a7a74013

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Artigo_Bento_ICNAAM2012.pdf
Size:
347.14 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: