Publication
Actigraph calibration in obese/overweight and type 2 Diabetes Mellitus middle-aged to old adult patients
dc.contributor.author | Lopes, Vitor P. | |
dc.contributor.author | Magalhães, Pedro | |
dc.contributor.author | Bragada, José A. | |
dc.contributor.author | Vasques, Catarina | |
dc.date.accessioned | 2010-10-26T14:37:36Z | |
dc.date.available | 2010-10-26T14:37:36Z | |
dc.date.issued | 2009 | |
dc.description.abstract | Background: Several methods exist to asses and control physical intensity levels of subjects engaged in physical activities programs, accelerometry is a method that could be easily used in the field. The purposes were: to calibrate Actigraph in middle-aged to old obese/overweight and DM2 adult patients; and to determine the threshold counts for sedentary, light, moderate, and vigorous physical activity (PA). Methods: Sample comprise 26 participants (62.6 ± 6.5 years of age) of both gender. Counts and VO2 were simultaneously assessed during: resting, seating, standing, walking at 2.5 km·h–1, 5 km·h–1, and 6 km·h–1. A hierarchical linear model was used to derive a regression equation between MET and counts. Receiver operating characteristics (ROC) analysis was used to define thresholds for PA levels. Results: The regression equation was: MET = 1.388400490262 + 0.001312683420044 (counts·min–1), r = .867. The threshold counts for sedentary-light, light-moderate and moderate-vigorous PA were: 200, 1240, 2400 counts·min–1 respectively. Conclusion: The Actigraph is a valid and useful device for the assessment of the amount of time spent in each PA intensity levels in obese/overweight and DM2 middle-aged to old adult patients. | por |
dc.identifier.citation | Lopes, Vítor P.; Magalhães, Pedro M.; Bragada, José A.; Vasques, Catarina (2009). Actigraph calibration in obese/overweight and type 2 Diabetes Mellitus middle-aged to old adult patients. Journal of Physical Activity and Health. ISSN 1543-3080. 6:1. p. S133-S140 | por |
dc.identifier.issn | 1543-3080 | |
dc.identifier.uri | http://hdl.handle.net/10198/2684 | |
dc.language.iso | eng | por |
dc.publisher | Human Kinetics | por |
dc.subject | Intervention study | por |
dc.subject | Exercise prescription | por |
dc.subject | Motion sensors | por |
dc.title | Actigraph calibration in obese/overweight and type 2 Diabetes Mellitus middle-aged to old adult patients | por |
dc.type | journal article | |
dspace.entity.type | Publication | |
oaire.citation.endPage | S140 | por |
oaire.citation.startPage | S133 | por |
oaire.citation.title | Journal of Physical Activity and Health | por |
person.familyName | Lopes | |
person.familyName | Magalhães | |
person.familyName | Bragada | |
person.familyName | Vasques | |
person.givenName | Vitor P. | |
person.givenName | Pedro | |
person.givenName | José A. | |
person.givenName | Catarina | |
person.identifier | 2316939 | |
person.identifier.ciencia-id | 531D-60D6-48BF | |
person.identifier.ciencia-id | 631D-E634-0FBB | |
person.identifier.ciencia-id | EC18-B34C-A1C8 | |
person.identifier.ciencia-id | 981C-32E4-DB4B | |
person.identifier.orcid | 0000-0003-1599-2180 | |
person.identifier.orcid | 0000-0003-2492-1499 | |
person.identifier.orcid | 0000-0001-7020-0583 | |
person.identifier.orcid | 0000-0002-8096-8390 | |
person.identifier.rid | D-1774-2011 | |
person.identifier.scopus-author-id | 17435197500 | |
person.identifier.scopus-author-id | 35224896200 | |
rcaap.rights | openAccess | por |
rcaap.type | article | por |
relation.isAuthorOfPublication | 9551b011-136c-42ca-a626-f0cedfbd0814 | |
relation.isAuthorOfPublication | ce33c577-a21a-4f32-9443-ea36d0af8d72 | |
relation.isAuthorOfPublication | d24f0ee1-6174-4249-8e0a-20629d306235 | |
relation.isAuthorOfPublication | 4ba39152-f023-4d26-a636-d64b80d8d41a | |
relation.isAuthorOfPublication.latestForDiscovery | 4ba39152-f023-4d26-a636-d64b80d8d41a |