Repository logo
 
Publication

Avaliação acústica dos ambientes de restauração do Instituto Politécnico de Bragança – Campus de Santa Apolónia

datacite.subject.fosEngenharia e Tecnologia::Engenharia Civilpt_PT
dc.contributor.advisorBraz-César, M.T.
dc.contributor.advisorRibeiro, Rodrigo Scoczynski
dc.contributor.authorAndrade, Fernanda Horst
dc.date.accessioned2020-12-22T10:48:46Z
dc.date.available2020-12-22T10:48:46Z
dc.date.issued2020
dc.date.submitted2019
dc.descriptionMestrado de dupla diplomação com a UTFPR - Universidade Tecnológica Federal do Paranápt_PT
dc.description.abstractO presente trabalho possui o intuito de analisar o tempo de reverberação dos ambientes internos dos espaços de restauração do Instituto Politécnico de Bragança – Campus de Santa Apolónia. A partir de medições in situ foram avaliados os ambientes de restauração comparando aos parâmetros estabelecidos pela Legislação vigente. A análise dos parâmetros acústicos serviu de base para a proposição de soluções construtivas que visam a melhora dos ambientes, para que os níveis de desempenho e conforto acústico sejam atingidos conforme os níveis recomendados. As avaliações do desempenho das soluções foram elaboradas utilizando o software I-SIMPA, de código aberto. As análises das simulações dos ambientes com as soluções acústicas permitiram concluir que os forros em materiais absorventes não apresentaram valores suficientes para satisfazer a Legislação quanto ao tempo de reverberação. A inserção de painéis verticais Broadband Compact Absorber (BCA), por sua vez, resultou em valores simulados condizentes com o exigido, e os parâmetros de definição de fala D50 e índice de decaimento inicial (EDT) também apresentaram valores satisfatórios com o BCA.pt_PT
dc.description.abstractIn this work, the reverberation time were analyzed for the internal environments of the Polytechnic Institute of Bragaça’s restaurant. By using in situ measurements, the were evaluated and compared to the parameters established by current legislation. The analysis of the acoustic parameters served as a basis for proposing constructive solutions aimed at improving the environments, so that the levels of acoustic performance and comfort can achieved the recommended levels. The evaluation of the solutions performance was elaborated using the ISIMPA software that has open source. The analysis of the simulations of the environments with the acoustic solutions allowed to conclude that the ceilings in absorbent materials did not present sufficient values to satisfy the standard parameters for reverberation time, on the other hand, the vertical panels Broadband Compact Absorber (BCA) presented values consistent with the required. The parameters of speech definition D50 and index of initial decay also presented satisfactory values with the BCA.pt_PT
dc.identifier.tid202567249pt_PT
dc.identifier.urihttp://hdl.handle.net/10198/22994
dc.language.isoporpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by-nc/4.0/pt_PT
dc.subjectAcústicapt_PT
dc.subjectCondicionamento acústicopt_PT
dc.subjectTempo de reverberaçãopt_PT
dc.titleAvaliação acústica dos ambientes de restauração do Instituto Politécnico de Bragança – Campus de Santa Apolóniapt_PT
dc.typemaster thesis
dspace.entity.typePublication
rcaap.rightsopenAccesspt_PT
rcaap.typemasterThesispt_PT
thesis.degree.nameEngenharia da Construçãopt_PT

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Andrade_Fernanda.pdf
Size:
5 MB
Format:
Adobe Portable Document Format