Damage localization in laminated composite plates using mode shapes measured by pulsed TV holography

dc.contributor.authorSantos, J.V. Araújo
dc.contributor.authorLopes, Hernani
dc.contributor.authorVaz, M.A.P.
dc.contributor.authorSoares, C.M. Mota
dc.contributor.authorFreitas, M.J.M.
dc.date.accessioned2011-04-12T10:13:35Z
dc.date.available2011-04-12T10:13:35Z
dc.date.issued2006
dc.descriptionThree methods for the damage localization of impact damage in laminated composite plates, based on their vibrational characteristics, are presented in this paper. These methods use double pulse TV holography with acoustic excitation for mode shapes acquisition and the differences in translations, rotations and curvatures. The rotations and curvatures are obtained by numerical differentiation of mode shapes translations using a differentiation/smoothing technique. The methods are applied to a carbon fiber reinforced epoxy rectangular plate, free in space, subjected to two cases of impact damage. It is shown that the method based on curvatures allows the localization of both cases of damage, which can be undetected by visual, X-ray or C-scan inspections. The best localizations are achieved by selecting and applying the method to the most changed mode.por
dc.description.abstractThree methods for the damage localization of impact damage in laminated composite plates, based on their vibrational characteristics, are presented in this paper. These methods use double pulse TV holography with acoustic excitation for mode shapes acquisition and the differences in translations, rotations and curvatures. The rotations and curvatures are obtained by numerical differentiation of mode shapes translations using a differentiation/smoothing technique. The methods are applied to a carbon fiber reinforced epoxy rectangular plate, free in space, subjected to two cases of impact damage. It is shown that the method based on curvatures allows the localization of both cases of damage, which can be undetected by visual, X-ray or C-scan inspections. The best localizations are achieved by selecting and applying the method to the most changed mode.por
dc.identifier.citationAraújo, J.V.; Lopes, H.; Vaz, M.; Mota Soares, C.M.; Mota Soares, C.A.; Freitas, M.J.M. de (2006). Damage localization in laminated composite plates using mode shapes measured by pulsed TV holography. Composite Structures. ISSN 0263-8223. p.272-281.por
dc.identifier.doi10.1016/j.compstruct.2006.06.034
dc.identifier.issn0263-8223
dc.identifier.urihttp://hdl.handle.net/10198/4010
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.relation.ispartofseries3;84
dc.subjectDamage localizationpor
dc.subjectLaminated platepor
dc.subjectMode shapepor
dc.subjectPulsed TV holographypor
dc.subjectAcoustic excitationpor
dc.subjectNon-destructive inspectionpor
dc.titleDamage localization in laminated composite plates using mode shapes measured by pulsed TV holographypor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage281por
oaire.citation.issue84por
oaire.citation.startPage272por
oaire.citation.titleComposite Structurespor
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
JV1.pdf
Size:
137.79 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: