Three methods for the damage localization of impact damage in laminated composite plates, based on their vibrational characteristics, are presented in this paper. These methods use double pulse TV holography with acoustic excitation for mode shapes acquisition and the differences in translations, rotations and curvatures. The rotations and curvatures are obtained by numerical differentiation of mode shapes translations using a differentiation/smoothing technique. The methods are applied to a carbon fiber reinforced epoxy rectangular plate, free in space, subjected to two cases of impact damage. It is shown that the method based on curvatures allows the localization of both cases of damage, which can be undetected by visual, X-ray or C-scan inspections. The best localizations are achieved by selecting and applying the method to the most changed mode.

Description

Three methods for the damage localization of impact damage in laminated composite plates, based on their vibrational characteristics, are presented in this paper. These methods use double pulse TV holography with acoustic excitation for mode shapes acquisition and the differences in translations, rotations and curvatures. The rotations and curvatures are obtained by numerical differentiation of mode shapes translations using a differentiation/smoothing technique. The methods are applied to a carbon fiber reinforced epoxy rectangular plate, free in space, subjected to two cases of impact damage. It is shown that the method based on curvatures allows the localization of both cases of damage, which can be undetected by visual, X-ray or C-scan inspections. The best localizations are achieved by selecting and applying the method to the most changed mode.

Keywords

Damage localization Laminated plate Mode shape Pulsed TV holography Acoustic excitation Non-destructive inspection

Citation

Araújo, J.V.; Lopes, H.; Vaz, M.; Mota Soares, C.M.; Mota Soares, C.A.; Freitas, M.J.M. de (2006). Damage localization in laminated composite plates using mode shapes measured by pulsed TV holography. Composite Structures. ISSN 0263-8223. p.272-281.

Research Projects

Organizational Units

Journal Issue