Repository logo
 
Publication

Flexural reinforcement with FRP systems - experimental results vs. Expected results based on actual design guidelines

dc.contributor.authorAzevedo, Diogo M.M.
dc.contributor.authorJuvandes, Luís
dc.contributor.authorHenriques, António
dc.date.accessioned2011-06-01T10:14:52Z
dc.date.available2011-06-01T10:14:52Z
dc.date.issued2005
dc.description.abstractDue to the specific characteristics of the fibre reinforced polymers (FRP), the structural behaviour of concrete elements reinforced by FRP systems as well as to other questions related to the use of the externally bonded reinforcement (EBR) technique, it is necessary to respect specific rules on the application of these systems to reinforce concrete elements. Actually, some recent manuals were published with the main objective of providing design guidelines for the use of FRP reinforcement in accordance with the actual design format for concrete structures such as American Concrete Institute Committee 440, CEB-FIB Task Group 9.3 and ISIS Canada Network of Centres of Excellence. The objective of this work is to appraise the suggested methodologies of the design manuals for the new strengthening technique by external bond of unidirectional FRP systems. A validation analysis was performed in this paper by a comparison of experimental test results with analytical prediction behaviour by the proposed design equations. A comparative analysis in ultimate limit state was carried out based on national and international studies recently published. Moments at ultimate, effective strains on the FRP, failure modes and type of system (prefabricate or cast in-situ) were compared. It was possible to conclude about some relevant parameters for design, as it is the definition of a value to the effective strain on the FRP reinforcement, the control of premature failure modes and the correct characterization of the FRP properties. From the discussion of the results obtained some conclusions are forwarded with regard to validate the proposed design models for composite reinforced behaviour.por
dc.identifier.citationAzevedo, Diogo; Juvandes, Luís; Henriques, António (2005). Flexural reinforcement with FRP systems - experimental results vs. Expected results based on actual design guidelines. In 3ª Conferência Internacional Composites in Construction CCC. Lyon, França.por
dc.identifier.urihttp://hdl.handle.net/10198/4837
dc.language.isoengpor
dc.peerreviewedyespor
dc.subjectpPepreg sheets and prefabricate laminates CFRP systemspor
dc.subjectDesign for flexurepor
dc.subjectMode of failurepor
dc.subjectMinimum flexural momentpor
dc.titleFlexural reinforcement with FRP systems - experimental results vs. Expected results based on actual design guidelinespor
dc.typeconference paper
dspace.entity.typePublication
oaire.citation.conferencePlaceLyon, Françapor
oaire.citation.title3ª Conferência Internacional Composites in Construction CCC2005por
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CCC2005-109_final.pdf
Size:
131.65 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: