| Name: | Description: | Size: | Format: | |
|---|---|---|---|---|
| 16.36 MB | Adobe PDF |
Advisor(s)
Abstract(s)
Light-gauge Steel Frame (LSF) walls are expanded nowadays due to several advantages, especially to achieve
economy, sustainability and improved structural performance. The latter has stimulated designers to adopt Cold
Formed Steel (CFS) members as primary components of LSF walls. However, the high thermal conductivity and
slenderness of CFS sections make them vulnerable to mechanical degradation during fire. While numerous
studies have investigated the performance of CFS stud walls under one-sided fire exposure, the investigation on
double-sided fire exposure remains limited, especially for built-up studs. This study investigates the performance
of CFS stud walls under compression loading, subjected to one-sided and double-sided fire exposure. Numerical
models were developed using ANSYS APDL, considering geometric imperfections, material nonlinearities and
contact element effect. The developed models were validated against previous experimental and numerical re-
sults. Various parameters were analysed through parametric study, including steel thickness and grades, web
stiffeners and I-shaped stud configurations. The results demonstrate the significant impact of the double-sided
fire exposure on CFS walls performance, reducing the fire resistance by 41 % and 50 % for CFS thicknesses of
1.15 mm and 1.5 mm, respectively, compared to one-sided fire exposure. Steel grade and I-shaped configurations
were found to significantly enhance the load-bearing capacity and fire resistance of CFS walls. The maximum
temperatures predicted for each load ratio were used to calculate the load ratio as per EN1993–1–2. New for-
mulas, based on load ratio were proposed to predict the maximum temperature at failure for CFS walls subjected
to one-sided and double-sided fire exposure. The findings will improve fire structural design codes of CFS walls,
by ensuring accurate predictions of limiting temperatures and fire resistance and providing engineers with
substantial data for LSF structures.
Description
Keywords
Light gauge steel frame (LSF) walls Cold formed steel (CFS) Web stiffeners Built-up I-shaped Numerical modelling Fire resistance
Pedagogical Context
Citation
Kada, Abdelhak; Kada, Abdelhak; Menadi, Belkacem; Lamri, Belkacem; Yessad, Ouissam; Piloto, P.A.G.; Jiang, Liming (2025). Performance of single and built-up I-shaped cold formed steel stud under double sided walls fire exposure. Engineering Structures. ISSN 0141-0296. 335, p. 1-18
Publisher
Elsevier