Two new formulae for the design of beam-columns at room temperature have been proposed into Eurocode 3, prEN 1993-1-1 (2002), and are the result of great efforts made by two working groups that followed different approaches, a French-Belgian team and an Austrian-German one. Under fire conditions the prEN 1993-1-2 (structural fire design) presents formulae, for the design of beam-columns based on the prENV 1993-1-1 (1992). In order to study the possibility of having, in part 1-1 and part 1-2 of the Eurocode 3, the same approach, a numerical research was made using the finite element program SAFIR, developed at the University of Liege for the study of structures subjected to fire.

Description

Keywords

Beam-column Buckling Lateral-torsional-buckling Fire Eurocode 3 Numerical modelling

Citation

Vila Real, P.M.M.; Lopes, N.; Silva, L.S; Piloto, P.A.G.; Franssen, J.-Marc (2003). Towards a consistent safety format of steel beam-columns: application of the new interaction formulae from ambient temperature to elevated temperatures. Steel and Composite Structures: International Journal. ISSN 1229-9367. 3:6 p.383-401