Microwave treatment of biological samples for methylmercury determination by high performance liquid chromatography-cold vapour atomic fluorescence spectrometry

dc.contributor.authorRamalhosa, Elsa
dc.contributor.authorRío-Segade, Susana
dc.contributor.authorPereira, Eduarda
dc.contributor.authorVale, Carlos
dc.contributor.authorDuarte, Armando
dc.date.accessioned2011-04-05T09:44:40Z
dc.date.available2011-04-05T09:44:40Z
dc.date.issued2001
dc.description.abstractA simple and rapid microwave-assisted alkaline digestion procedure was developed in combination with high performance liquid chromatography-ultraviolet post-column oxidation-cold vapour atomic fluorescence spectrometric detection for methylmercury determination in biological tissues. Since the stability of methylmercury in methanolic potassium hydroxide solution under microwave irradiation was verified, the microwave-assisted extraction procedure was optimized in terms of quantitative recovery of methylmercury and minimum time required. The alkaline extracts were subjected to clean-up steps with dichloromethane and hydrochloric acid in order to reduce matrix interferences in methylmercury determination. The effects of matrix interferences were checked by comparison of the slopes corresponding to calibration and standard addition curves. The accuracy of the method was evaluated by the analysis of two biological certified reference materials, NRC TORT-2 and BCR 463. The results obtained by the proposed method were in good agreement with the certified values of methylmercury concentration in both materials. The detection limit was 10 mug kg(-1) and the relative standard deviation was < 8% for methylmercury concentrations ranging from 0.15 to 3.0 mg kg(-1).por
dc.identifier.citationRamalhosa, Elsa; Río-Segade, Susana; Pereira, Eduarda; Vale, Carlos; Duarte, Armando (2001). Microwave treatment of biological samples for methylmercury determination by high-performance liquid chromatografy – cold vapour - atomic fluorescence spectrometry. Analyst. ISSN 0003-2654. 126:9, p. 1583-1587por
dc.identifier.doi10.1039/b104041n
dc.identifier.urihttp://hdl.handle.net/10198/3950
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherThe Royal Society of Chemistrypor
dc.relation.ispartofseries126;
dc.subjectMethylmercurypor
dc.subjectMicrowave treatmentpor
dc.subjectBiological samplespor
dc.subjectHPLC-CV-AFSpor
dc.titleMicrowave treatment of biological samples for methylmercury determination by high performance liquid chromatography-cold vapour atomic fluorescence spectrometry
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage1587por
oaire.citation.startPage1583por
oaire.citation.titleAnalystpor
person.familyNameRamalhosa
person.givenNameElsa
person.identifier.ciencia-id1A1D-FC05-A05D
person.identifier.orcid0000-0003-2503-9705
person.identifier.scopus-author-id6602978189
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublicationd74be6c0-1703-4f77-bd81-e289ec981ee3
relation.isAuthorOfPublication.latestForDiscoveryd74be6c0-1703-4f77-bd81-e289ec981ee3

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Analyst 2001.pdf
Size:
179.07 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: