Repository logo
 
Publication

Monitoring historical masonry structures with operational modal analysis: two case studies

dc.contributor.authorRamos, Luis F.
dc.contributor.authorMarques, Leandro
dc.contributor.authorLourenço, Paulo B.
dc.contributor.authorRoeck, G.
dc.contributor.authorCosta, Alfredo Campos
dc.contributor.authorRoque, João
dc.date.accessioned2012-07-02T10:21:22Z
dc.date.available2012-07-02T10:21:22Z
dc.date.issued2010
dc.description.abstractThe paper addresses two complex case studies of modal and structural identification of monuments in Portugal: the ClockTower of Mogadouro and the Church of Jerónimos Monastery, in Lisbon. These are being monitored by University of Minho with vibration, temperature and relative air humidity sensors. Operational modal analysis is being used to estimate the modal parameters, followed by statistical analysis to evaluate the environmental effects on the dynamic response .The aim is to explore damage assessment in masonry structures at a nearly stage by vibration signatures, as a part of a health monitoring process that helps in the preservation of historical constructions. The paper presents the necessary preliminary dynamic analysis steps before the monitoring task, which includes installation of the monitoring system, system identification and subsequent FE model updating analysis, automatic modal identification and investigation of the Influence of the environment on the identified modal parameters.por
dc.identifier.citationRamos, L.F.; Marques, L.; Lourenço, P.B.; DeRoeck, G.; Campos-Costa, A.; Roque, J.A. (2010). Monitoring historical masonry structures with operational modal analysis: two case studies. Mechanical Systems and Signal Processing. ISSN 0888-3270. 24:5, p. 1291-1305por
dc.identifier.doi10.1016/j.ymssp.2010.01.011
dc.identifier.issn0888-3270
dc.identifier.urihttp://hdl.handle.net/10198/7094
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherElsevierpor
dc.subjectDamage identificationpor
dc.subjectMasonry structurespor
dc.subjectExperimental testingpor
dc.subjectModal analysispor
dc.titleMonitoring historical masonry structures with operational modal analysis: two case studiespor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.issueVolume 24, Issue 5, pp. 1291-1305por
oaire.citation.titleMechanical Systems and Signal Processingpor
person.familyNameRoque
person.givenNameJoão
person.identifier.ciencia-id3E12-8A64-25B7
person.identifier.orcid0000-0002-1043-0405
person.identifier.scopus-author-id10045302900
rcaap.rightsrestrictedAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication05fc9269-29cc-436a-9d4b-8b3a9898c142
relation.isAuthorOfPublication.latestForDiscovery05fc9269-29cc-436a-9d4b-8b3a9898c142

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
2010_Elsevier_JRoque.pdf
Size:
4.14 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: