Logo do repositório
 
Publicação

Measuring the cell-free layer in circular microchannels

dc.contributor.authorFidalgo, Cátia
dc.contributor.authorLima, Rui A.
dc.contributor.authorOliveira, Mónica
dc.contributor.authorIshikawa, Takuji
dc.contributor.authorImai, Yohsuke
dc.contributor.authorYamaguchi, Takami
dc.date.accessioned2011-05-30T10:05:19Z
dc.date.available2011-05-30T10:05:19Z
dc.date.issued2010
dc.description.abstractOne of the most interesting hemodynamic phenomenon observed both in vivo and in vitro studies is known as Fahraeus-Lindqvist effect, in which the apparent blood viscosity decreases as the tube diameter is reduced, for narrow tubes (< 300 μm). The physical reason behind this phenomenon is the creation of a marginal cell-free layer at regions adjacent to the tube wall. Although intensively studied, the complex formation of the cell-free layer has not yet been convincingly described mainly due to multi-physical and hemorheological factors that affect this phenomenon. The main purpose of this experimental work is to study the effect of the hematocrit (Hct) and temperature on the thickness of the cell-free layer in both glass capillaries and circular polydimethylsiloxane (PDMS) microchannels using an optical technique. The internal diameter of the glass and PDMS microchannels are 100 m and 73±2 m, respectively. The microchannels were placed on the stage of the inverted microscope and the temperature of the stage was adjusted by means of a thermo plate controller. The flow rate of the working fluids was controlled using a syringe pump. The images were recorded using a confocal microscopy system and transferred to the computer to be evaluated in Image J (NIH) using different plug-ins (MTrackJ and FeatureJ). The recorded images show a clear formation of a cell-free layer of variable thickness depending on experimental conditions.por
dc.identifier.citationFidalgo, C.; Lima, Rui; Oliveira, M.; Ishikawa, T.; Imai, Y.; Yamaguchi, T. (2010). Measuring the cell-free layer in circular microchannels. In 6th World Congress of Biomechanics. Singapure.por
dc.identifier.urihttp://hdl.handle.net/10198/4688
dc.language.isoengpor
dc.peerreviewedyespor
dc.subjectCell-free layerpor
dc.subjectMicrochannelspor
dc.titleMeasuring the cell-free layer in circular microchannelspor
dc.typeconference object
dspace.entity.typePublication
oaire.citation.conferencePlaceSingapurepor
oaire.citation.title6th World Congress of Biomechanicspor
person.familyNameLima
person.givenNameRui A.
person.identifier.ciencia-idEE12-C3FB-349D
person.identifier.orcid0000-0003-3428-637X
person.identifier.ridH-5157-2016
person.identifier.scopus-author-id18437397800
rcaap.rightsopenAccesspor
rcaap.typeconferenceObjectpor
relation.isAuthorOfPublication7b50c499-8095-4f4f-8b1b-fa7388e4ff62
relation.isAuthorOfPublication.latestForDiscovery7b50c499-8095-4f4f-8b1b-fa7388e4ff62

Ficheiros

Principais
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
AbsWCB2011.pdf
Tamanho:
1.71 MB
Formato:
Adobe Portable Document Format
Licença
A mostrar 1 - 1 de 1
Miniatura indisponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: