Repository logo
 
Publication

Optic disc detection by earth mover's distance template matching

dc.contributor.authorMonteiro, Fernando C.
dc.contributor.authorCadavez, Vasco
dc.date.accessioned2012-07-03T09:07:15Z
dc.date.available2012-07-03T09:07:15Z
dc.date.issued2011
dc.description.abstractThis paper presents a method for the detection of OD in the retina which takes advantage of the powerful preprocessing techniques such as the contrast enhancement, Gabor wavelet transform for vessel segmentation, mathematical morphology and Earth Mover’s distance (EMD) as the matching process. The OD detection algorithm is based on matching the expected directional pattern of the retinal blood vessels. Vessel segmentation method produces segmentations by classifying each image pixel as vessel or nonvessel, based on the pixel’s feature vector. Feature vectors are composed of the pixel’s intensity and 2D Gabor wavelet transform responses taken at multiple scales. A simple matched filter is proposed to roughly match the direction of the vessels at the OD vicinity using the EMD. The minimum distance provides an estimate of the OD center coordinates. The method’s performance is evaluated on publicly available DRIVE and STARE databases. On the DRIVE database the OD center was detected correctly in all of the 40 images (100%) and on the STARE database the OD was detected correctly in 76 out of the 81 images, even in rather difficult pathological situations.por
dc.identifier.citationMonteiro, Fernando C.; Cadavez, Vasco (2011). Optic disc detection by earth mover's distance template matching. International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering. ISSN 1307-6892. 5:11, p. 617-621por
dc.identifier.issn1307-6892
dc.identifier.urihttp://hdl.handle.net/10198/7113
dc.language.isoengpor
dc.peerreviewedyespor
dc.publisherWorld Academy of Science, Engineering and Technology (WASET)por
dc.subjectDiabetic retinopathypor
dc.subjectEarth Mover’s distancepor
dc.subjectGabor waveletspor
dc.subjectOptic disc detectionpor
dc.subjectRetinal imagespor
dc.titleOptic disc detection by earth mover's distance template matchingpor
dc.typejournal article
dspace.entity.typePublication
oaire.citation.conferencePlaceVeneza - Itáliapor
oaire.citation.endPage1258por
oaire.citation.issue59por
oaire.citation.startPage1254por
oaire.citation.titleInternational Conference on Medical Image and Signal Computingpor
person.familyNameMonteiro
person.familyNameCadavez
person.givenNameFernando C.
person.givenNameVasco
person.identifierR-000-HDG
person.identifier.ciencia-id2019-BDBF-10E2
person.identifier.ciencia-id441B-01AB-A12E
person.identifier.orcid0000-0002-1421-8006
person.identifier.orcid0000-0002-3077-7414
person.identifier.ridH-9213-2016
person.identifier.ridA-3958-2010
person.identifier.scopus-author-id8986162600
person.identifier.scopus-author-id9039121900
rcaap.rightsopenAccesspor
rcaap.typearticlepor
relation.isAuthorOfPublication363b6c37-282c-4cd6-bb54-3c97cc700d78
relation.isAuthorOfPublication57b410e9-f6b7-42ff-ab3d-b526278715eb
relation.isAuthorOfPublication.latestForDiscovery57b410e9-f6b7-42ff-ab3d-b526278715eb

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
Optic-Disc-Detection-by-Earth-Movers-Distance-Template-Matching.pdf
Size:
691.92 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: