A high performance liquid chromatographic (HPLC) method for the determination
of tocopherols and tocotrienols in walnut samples is described. The
compounds were extracted with n-hexane, using a simple solid-liquid extraction
procedure. Tocol was used as internal standard and BHT as anti-oxidant. The ehromatographic
separation was achieved using an Inertsil 5 SI normal phase column
operating with isocratic elution of n-hexane/1,4-dioxane (96.5:3.5, v/v), at a flow
rate of 0.7 mL/min. The effluent was monitored by a series arrangement of a diodearray
detector followed by a fluorescence detector. The detection limits were
low, between 0.037 and 0.266 (jig/mL. The method was precise (% CV less than2.8%), accurate (% CV less than 5.6%), and, as a general rule, the recovery values were
high (mean values ranging from 93.4% to 104%).