Repository logo
 
No Thumbnail Available
Publication

Load carrying capacity of partially encased columns for different fire ratings

Use this identifier to reference this record.
Name:Description:Size:Format: 
FELLOUH resumo.pdf206.25 KBAdobe PDF Download

Advisor(s)

Abstract(s)

Partially encased columns have significant fire resistant. However, it is not possible to assess the fíre resistance of such members simply by considering the temperature of the steel. The presence of concrete increases the mass and thermal inertia of the member and the variation of temperatures within the cross section, in both the steel and concrete components. The annex G of EN 1994-1-2 [1] allows to calculate the load carrying capacity of partially encased columns, for a specific fire rating time, considering the balanced summation method. New formulas will be used to calculate the plastic resistance to axial compression and the effective fíexural stiffness. These two parameters are used to calculate the buckling resistance, assuming the most appropriate buckling curve of EN1993-1-1 [2]. The finite element method is used to determine which curve best fits the buckling resistance for different fire ratings of 30, 60, 90 and 120 minutes.

Description

Keywords

Fire Partially encased columns Balanced summation method Buckling Numerical simulation

Citation

Abdelkadir, Fellouh; Benlakehal, Nourredine; Piloto, P.A.G.; Ramos, Ana; Mesquita, L.M.R. (2016). Load carrying capacity of partially encased columns for different fire ratings. In 5th workshop in Urban Fire Safety. Lisbon, Portugal

Research Projects

Organizational Units

Journal Issue