Partially encased columns have significant fire resistant. However, it is not possible to assess
the fíre resistance of such members simply by considering the temperature of the steel. The
presence of concrete increases the mass and thermal inertia of the member and the variation of
temperatures within the cross section, in both the steel and concrete components. The annex G
of EN 1994-1-2 [1] allows to calculate the load carrying capacity of partially encased columns, for
a specific fire rating time, considering the balanced summation method. New formulas will be
used to calculate the plastic resistance to axial compression and the effective fíexural stiffness.
These two parameters are used to calculate the buckling resistance, assuming the most
appropriate buckling curve of EN1993-1-1 [2]. The finite element method is used to determine
which curve best fits the buckling resistance for different fire ratings of 30, 60, 90 and 120
minutes.
Description
Keywords
Fire Partially encased columns Balanced summation method Buckling Numerical simulation