A resistência ao fogo de pilares parcialmente revestidos, dependem da evolução da temperatura durante a exposição ao fogo. Este trabalho visa avaliar o efeito do método da soma pesada na conceção da carga resistente à encurvadura de pilares parcialmente revestidos em situação de incêndio, de acordo com as normas europeias.
The fire resistance of partially encased columns depends on the temperature evolution during fire exposure. This work aims to evaluate the effect of the balanced summation model on the design of the buckling resistance of partially encased columns under fire condittion, in accordance with European standards.
The fire resistance of partially encased columns depends on the temperature evolution during fire exposure. This work aims to evaluate the effect of the balanced summation model on the design of the buckling resistance of partially encased columns under fire condittion, in accordance with European standards.
Description
Mestrado com dupla diplomação com a Universidade Tecnológica Federal do Paraná
Keywords
Colunas mistas parcialmente revestidas Resistência ao fogo Método avançado de cálculo Carga resistente à encurvadura